TM 5-6640-213-14
Preventive Maintenance Checks and Services (PMCS) - Continued
NOTE: Within designated interval, these checks are to be performed in the
o r d e r listed.
M - Monthly
A - After
B - Before
C - Combat Operability Check
M - Monthly
D - During
Procedures
Interval
Equipment is not
Check for and have repaired
Item to be
Item
Ready/Available
or adjusted as necessary
M
Inspected
No.
O b s e r v e compressor gage
for indications of unusual or
u n s a t i s f a c t o r y performance
o f compressor.
Check compressor air pipes
for indications of leaks.
Check piping for leaks or
Water
2
l o o s e n e s s . Make sure outlet
Pump
valves are closed.
Make sure tank contains
sufficient water.
Inspect pump and motor for
unusual noises or smells that
could indicate malfunction.
Make sure pump does not
leak at shaft seal.
Make sure all outlet valves
deliver full flow when open
and do not leak when closed.
Remove fill cap from water
tank and fill tank with water.
Take care to prevent
impurities from entering
tank.
3-3
|