TM 5-6350-275-24&P
3-94.
REPLACE J-SIIDS GANYMEDE-B INTERFACE ASSEMBLY. (See Figure 3-47).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
equipment.
Materials/Parts:
J-SIIDS Ganymede Interface Assembly
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Replace
(1) Remove the slip-on terminal board strips from TB-1 (4), TB-2 (5), TB-6 (6) and TB-5 (2).
(2) Press in and hold latching mechanism (*) down on each plastic standoff (7), while gently lifting up on
Ganymede B PWA (1). Do this for each of the four latching mechanisms until the PWA can be removed
from enclosure (3).
(3) Place the removed Ganymede B PWA into a ESD protective bag.
b. Installation
(1) Set the link settings and/or switch settings exactly the same as on removed assembly, or refer to Appendix
E, page E-13, for PWA settings.
(2) Place the Ganymede B PWA (1) on plastic standoffs and gently press down on PWA until each of the
latching mechanism locks into place.
(3) Connect slip-on terminal strips to TB-1 (4), TB-2 (5), TB-5 (2) and TB-6 (6).(Ensure each terminal strip is
properly lined up with terminal pins)
(4) Reconnect input power.
(5) Close the front access door on enclosure (3) and secure.
3-183
|