TM 5-6350-275-24&P
3-91.
REPLACE J-SIIDS LEDA INTERFACE ASSEMBLY (Hinged). (See Figure 3-46).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
Tools:
equipment.
Screwdriver, Flat tip, (Item 7, App B)
Materials/Parts:
J-SIIDS Leda Interface Assembly (Hinged)
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Replace
(1) Tag and remove the slip-on terminal strip from the Leda Flex PWA (3) TB-7 (4).
(2) Tag and remove slip-on terminal strips from Leda Flex Termination PWA (1) TB-1, TB-2, TB-3, TB-4, TB-
5, TB-6 (11), TB-7 (10), and TB-8 (9) by gently lifting up on sides of terminal strips.
(3) Using a flat tip screwdriver, remove screw (8), and lower the hinged panel assembly (5).
(4) Using a flat tip screwdriver, remove the two screws (6) holding the J-SIIDS Leda Interface Assembly (5) to
the J-SIIDS enclosure (12) and remove.
b. Installation
(1) Align the J-SIIDS Leda Interface Assembly (5) up with the two J-SIIDS enclosure standoffs and secure the
Assembly with two screws (6).
(2) Raise the hinged panel assembly (5) and secure to J-SIIDS enclosure (12) with screw (8).
(3) Using a flat tip screwdriver, connect the tagged wires to TB-1 through TB-6 (11), TB-7(10) and TB-8 (9).
(4) Connect the tagged slip-on terminal strip to Leda Flex PWA (3) TB-7 (4).
(5) Reconnect input power.
(6) Close, lock and secure the J-SIIDS enclosure door.
3-179
|