TM 5-6350-275-24&P
3-79.
REPLACE 12 VDC BATTERY. (See Figure 3-43).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Materials/Parts:
Wear ESD wriststrap while working on
12 VDC battery
equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Remove the two slip-on terminals from Battery (27) positive and negative terminals.
(2) Remove Battery (27) from enclosure.
b. Installation
(1) Place Battery (27) in bottom of enclosure.
(2) Connect the two slip-on terminals to Battery (27) positive and negative terminals.
(3) Reconnect input power.
(4) Replace enclosure cover and secure.