TM 5-6350-275-24&P
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on equipment.
Enclosure access cover removed
Wear ESD wriststrap while working on equipment
Tools:
Screwdriver, flat tip, (Item 6, App B)
Screwdriver, flat tip, (Item 7, App B)
Materials/Parts:
12 point Sub-RADC (Leda) Assembly
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Remove slip on terminal strip from TB-7 (3).
(2) Remove slip on terminal strips (12), (11) and (10) from Leda Flex termination PWA (1).
(3) Using a flat tip screwdriver, remove the five screws (9) holding the Leda Panel Assembly (13) to enclosure
and remove the Leda Panel Assembly (13).
b. Installation
(1) Align the Leda Panel Assembly (13) mounting holes up with the enclosure standoffs and secure with five
screws (9).
(2) Reconnect slip on terminal strip to Leda Flex PWA TB-7 (3).
(3) Connect the slip on terminal strips (12), (11) AND (10) to Leda Flex termination PWA.
(4) Replace enclosure cover and secure.
3-154
|