3-69. REPLACE IN-LINE FUSE. (See Figure 3-41).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on equipment.
Enclosure access cover removed.
Tools:
Wear ESD wriststrap while working on equipment
Screwdriver, flat tip, (Item 6, App B).
Materials/Parts:
Fuse, 1 AMP, 250 VAC
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Open the In-line Fuse Holder located on input power terminal board (24).
(2) Using the flat tip screwdriver, gently lift up on fuse (11) and remove fuse from power terminal (24).
b. Installation
(1) Align fuse (11) on power terminal (24) and gently press down on fuse, until fuse locks into place.
(2) Close the In-line fuse holder on power terminal (24).
(3) Reconnect input power.
(4) Replace enclosure cover and secure.