Click here to make tpub.com your Home Page

Page Title: REPLACE LEDA FLEX TERMINATION PWA.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6350-275-24&P
3-64. REPLACE LEDA FLEX TERMINATION PWA. (See Figure 3-41).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on equipment.
Enclosure access cover removed
Materials/Parts:
Wear ESD wriststrap while working on equipment.
Leda Flex Termination card PWA
WARNING
Shut off power source before attempting to disconnect, service, or connect wires
or cables. Failure to do so may result in serious injury or death.
a. Removal
(1) Remove ribbon cable (4) from Leda Flex Termination PWA (1) connector PL1.
(2) Remove the slip-on terminal board strips from TB-1 through TB-6 (22), TB-7 (21) and TB-8 (20).
(3) Press out on side of snap track PWA holder (e) and remove the Leda Flex Termination PWA (1).
(4) Place the removed PWA into an ESD protective bag.
b. Installation
(1) Set link settings and/or switch settings exactly the same as removed PWA or refer to Appendix E, page E-
46.
(2) Press out on side of snap track PWA holder (e) and install Leda Flex Termination PWA (1) in snap track
alignment slots and release.
(3) Connect the slip-on terminal board strips to TB-1 through TB-6 (22), TB-7 (21) and TB-8 (20).
(4) Connect ribbon cable (4) to Leda Flex Termination PWA connector PL1.
(5) Reconnect input power.
(6) Replace enclosure cover and secure.
3-147

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business