TM 5-6350-275-24&P
Table 2-1. Unit Preventive Maintenance Checks and Services for the ICIDS
Item
Interval
Location: Item to
Procedures
No.
Check/Service
1
Semi-Annual
CCTV Cameras and
Check for loose cable connections, damage or frayed cables,
Housings
(Interior
missing hardware, and visible damage to the housing assembly.
and Exterior)
Clean housing assembly as necessary with clean water and dry with
clean wiping rags (Appendix D, Item 12). Clear camera lens field of
view as necessary. Check air pressure for all pressurized camera
housing.
2
Semi-Annual
CCTV
Camera
Check for loose or missing hardware and any visible damage to the
supports
camera support. Check hinge pins (if applicable) for rust. Clean and
apply lubricant as required to cantilever support, etc. (Appendix D,
Item 11).
3
Semi-Annual
Sensors
(outdoor,
Check for loose or missing hardware on mounting brackets, and any
pole
mounted,
visible damage to transceiver assembly. Check mounting hardware
transmitter/ receiver
for rust; clean and lubricate hinge points as necessary (Appendix D,
units
Item 11). Check for loose cable connections and frayed cables.
Remove snow, ice, dirt, and other matter as necessary.
4
Semi-Annual
Sensors
(outdoor,
Check for loose or missing hardware on mounting brackets, and any
fence mounted)
visible damage to processor assembly or sensors. Check for loose
cable connections, frayed or cut cables. Remove any debris from
fence or fence line.
5
Semi-Annual
Uninterruptible Power
Clean the UPS unit with a damp cloth and dry with clean wiping rags
Supply (UPS)
6
Semi-Annual
Tape
Streamer
Clean tape head using head cleaning kit (Appendix D, Item 2). (See
Module
7
Annual
Floppy Diskette Drive
Clean using disk cleaning kit (Appendix D, Item 1). (See paragraph
2-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |