![]() TM5-6350-264-14&P-6 
NAVELEX EE181-AA-OMI-1/E121 DT-545 
TO 31S9-2FSS9-1-6 
CHAPTER 6 
REPAIR OF GRID WIRE SENSOR 
6-1. REPAIR OF GRID WIRE. Repair of the grid wire 
6-2. CHECKOUT PROCEDURE. 
After repair, 
test 
is restricted to reconnecting/patching a broken wire. 
GWS for proper operation. 
a. Remove covering as necessary to locate broken 
a. Tag and disconnect grid wires from TBl-1 and TB1- 
wire. 
2. Set multimeter to ohms and connect leads to 
wires removed from TBl-1 and TB1-2.  Meter 
b. Clean coating (1/2 inch, 1.27 cm) from ends of 
should indicate less than 2 ohms. 
broken wire and piece of wire to be used as patch. 
b. Tag and disconnect grid wires from TB1-3 and TB1- 
c. Using a crimp connection method, attach patch wire 
4.  Connect meter leads to wires removed from 
to broken wire ends of installed grid wire. 
TB1-3 and TB1-4.Meter should indicate less than 2 
ohms. 
d. Install previously removed covering (if applicable). 
c. Remove meter leads from TB1-3 and TB1-4. 
Reconnect wires to TB1. 
6-1/(6-2 blank) 
 | 
| 
 