CHAPTER 1 
INTRODUCTION 
Section I. GENERAL 
destruction of Army materiel to prevent enemy use are 
1-1. SCOPE. This manual is for your use in operating 
contained in TM 750-244-3. 
and maintaining the Grid Wire Sensor (GWS) Model DT- 
545/FSS-9(V) in its operational environment. The GWS 
1-5. QUALITY  ASSURANCE/QUALITY  CONTROL. 
is an integral part of the Joint Services Interior Intrusion 
Detection System (J-SIIDS).  For information on the 
There are no Quality Assurance/Quality Control technical 
major assemblies of J-SIIDS, refer to the applicable 
manuals applicable to this equipment. 
manual listed in appendix A. 
1-6. REPORTING 
EQUIPMENT 
IMPROVEMENT 
1-2. MAINTENANCE  FORMS  AND  RECORDS. 
RECOMMENDATIONS (EIR). EIR's will be prepared on 
Equipment maintenance forms and procedures for their 
Standard  Form  368,  Quality  Deficiency  Report. 
use are contained in DA Pamphlet 738-750, the Army 
Instructions for preparing EIR's are provided in DA 
Maintenance Management System (TAMMS). 
Pamphlet 738-750. EIR's should be mailed directly to 
Commander, U.S.  Army Troop Support Command, 
1-3. ADMINISTRATIVE STORAGE.  Instructions for 
ATTN: AMSTR-QX, 4300 Goodfellow Blvd., St. Louis, 
administrative storage are contained in TM 740-90-1. 
Missouri 63120-1798. A reply will be furnished directly to 
you. 
1-4. DESTRUCTION  OF  ARMY  MATERIAL 
TO 
1-7. EQUIPMENT 
SERVICEABILITY 
CRITERIA 
PREVENT ENEMY USE. Instructions for the 
(ESC). This equipment is not covered by an ESC. 
Section II. DESCRIPTION AND DATA 
1-8. DESCRIPTION. The GWS consists of a wire grid 
1-9. TABULATED DATA. 
in four inch squares and a steel chassis (fig. 1-1) 
containing a component mounting plate, a terminal strip, 
a. Identification Data. An identification plate (Fig. 1- 
2) is located on the inside front cover. 
a pry-off alarm switch, and a cover tamper alarm switch 
(TAS).  The chassis has a removable cover and an 
b. Equipment Characteristics. 
access hole where interconnecting wiring is brought in 
through conduit. The wire grid is made of continuous 
(1) GWS Assembly 
horizontal and vertical wires and can cover up to 160 
square feet in any shape.  Depending on the barrier 
Weight ............................... 6.7 pounds (3.1 kg) 
material, the grid wire is stapled directly to the barrier or 
'to 'a foundation board that is secured to the barrier. 
Dimensions (overall) 
Fire-resistant panels are then installed over the grid wire 
for protection against daily abuse and visual detection. 
Height ............................. 2.68 inches (6.8 cm) 
Width .............................. 4.30 inches (11 cm) 