TM 43-0156
Step
Function
Mech
Insp
3
2 Secure ladder and steps to the catwalk with "J"
cont
bolts fabricated from flat washers (5310-00-833-
3340), nuts (5310-00-720-8528), and bolts (530o-
00-3282-4281).
(m) Access Doors.
1 Coat the rubber door seals with silicone (6850-00-
295-7685).
2 Securely lock all outside access doors and seal
with tape (7510-00-916-9659). Tape 7510-00-890-
9875 may be used as a substitute.
3 Place the keys with logbook.
(n) Marking. Mark power unit in accordance with
shroud end).
(o) Depreservation Guide.
1 Complete two DA Forms 2258.
2 Place one copy in a plastic bag (8105-00-902-
6508), heat seal or staple bag, and mark the bag
to indicate "DEPRESERVATION GUIDE."
3 Secure the preserved guide to the control panel in
the control unit.
4 Place the other copy in the logbooks.
b. Control Unit.
(1) Main Air Circuit Breakers.
(a) Remove the arc chutes (nine) and phase barriers.
(b) Install phase barriers back onto the breakers.
(c) Wrap the arc chutes with cushioning (8135-00-855-6969).
(d) Place arc chutes into the three plywood boxes
(37-3/4 x 21 x 32) marked "ARC CHUTES."
(e) Isolate the arc chutes from the sides of the box
and each other by using 21 x 2 x 4 block (5510-00-
220-6194). Seal box.