Step
Function
Mech
Insp
3
CAUTION
cont
Prelube unit before starting if unit has not been run during the last 24 hours.
9 Ensure that there is only sufficient fuel (approx
30 gl) in the fuel tank to warm the engine.
10 Start the engine on fuel and operate at fast idle
until thoroughly warm, then accelerate to
three-fourths speed. When the sight glass snows
foam, add preservative oil (9150-00-281-2007) to
the fuel tank.
11 Operate the engine until undiluted preservative
oil is observed flowing through the fuel return
sight glass.
12 Open drain valve and drain the preservative oil
from the fuel tank.
13 Close drain valve.
14 Atomize spray the interior of the fuel tank with
preservative oil (9150-00-111-0209) and seal open-
ing with tape (7510-00-916-9659). Tape 7510-00-
890-9875 may be used as a substitute.
(c) Crankcase and Oil System.
NOTE
Allow sufficient time for engine to cool before processing oil system.
1 Completely drain the crankcase, oil filters, and
lube oil strainer.
2 Remove oil filter elements.
3 Connect a portable pump to the output of the scav-
enging oil pump.
4 Pump preservative oil (9150-00-111-0209) until
preservative oil is observed in the lube strainer.
5 Disconnect pump from the scavenging pump.
6 Connect portable pump to the lube pump output.
Change 1