TM 43-0156
Step
Function
Mech
Insp
2
(2) Compressor.
cont
(a)
Drain normal lubrication oil from crankcase.
(b)
Fill crankcase with MIL-L-21260, type I, grade 30
preservative oil.
(c)
Remove the air cleaner element.
(d)
Atomize spray air intake with MIL-L-21260, type I,
grade 30 preservative oil while manually cranking
compressor.
(e)
Atomize spray the interior surfaces of the air
cleaner with MIL-L-21260, type I, grade 30
preservative oil.
(f)
Drain excess preservative.
(g)
Install the element.
(h)
Wrap air filter with MIL-B-121 barrier and secure
with MIL-T-22085 tape. PPP-T-60 tape may be used
as a substitute.
(i)
Prepare a UU-T-81 tag indicating "CRANKCASE
FILLED TO OPERATING LEVEL WITH PRESER-
VATIVE OIL GOOD FOR OPERATION UNTIL
FIRST REQUIRED LUBRICANT CHANGE - DO NOT
DRAIN - CHECK OIL LEVEL - IF LOW, FILL TO
OPERATING LEVEL WITH OIL AS SPECIFIED IN
LO 5-6115-550-12."
(j)
Attach the tag to the compressor.
(k)
Plug compressor output openings using MIL-C-5501
plugs or cover with MIL-T-22085 tape. PPP-T-60
tape may be used as a substitute.
(3) Drive Belts and Pulleys.
(a)
Remove drive belts.
(b)
Paint unpainted surface of pulley grooves with
TT-P-664 primer.
(c)
Install belts but do not tighten.
(d)
Prepare a UU-T-81 tag indicating "BELT TENSION
RELIEVED, ADJUST PRIOR TO STARTING."
(e)
Attach tag to belt guard.
Change 1
B-2-25
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |