Step
Function
Mech
Insp
3
(2) Air Start System.
cont
NOTE
The power plant may contain either an air or electric starting
system. No preservation is required for the electric start.
(a)
Fill the oiler reservoir for the air starter with
preservative oil (9150-00-111-0209).
(b)
Fully open the metering valve and run the air
starter until oil can be detected at the exhaust.
(3) Fuel System.
(a)
Remove fuel gage float assembly. Preserve float
assembly as follows:
1 Wrap float assembly in barrier (8135-00-226-3124),
cushion with cushioning (8135-00-855-6969) and
place into a fiberboard box (18 x 6 x 4). Seal
box with tape (7510-00-297-6655).
2 Secure box inside of engine control panel with
tape (7510-00-916-9659). NSN 7510-00-890-9875
may be used as a substitute.
3 Prepare tag (8135-00-292-2345) to indicate "FUEL
GAGE FLOAT ASSEMBLY STORED INSIDE ENGINE
CONTROL PANEL."
4 Attach the tag to the engine control pa el.
n
(b)
Connect auxiliary fuel lines to a container of
preservative oil (9150-00-281-2007).
(c)
Start the engine on fuel and operate at fast idle
until thoroughly warm, then accelerate to
three-fourths speed.
(d)
Switch the fuel supply to auxiliary.
(e)
Operate the engine until undiluted preservative
oil is observed flowing through the fuel return
sight glass.
(f)
Disconnect auxiliary fuel supply lines.
Change 1