Click here to make tpub.com your Home Page

Page Title: Fill dry-charged battery as follows:
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 43-0156
Step
Function
Mech
Insp
4
cont
WARNING
Do not add electrolyte solution to a battery that has been filled
previously. Add only distilled water to a battery in service; add
electrolyte only to a dry battery.
c.
Fill each cell of a dry battery with electrolyte to the
level indicated on the vent plug or cell cover.
(1) In temperate climates, use electrolyte of 1.280
specific gravity at 80 (27 ).
F
C
(2) The battery and electrolyte must be 60 (16 ) or
F
C
higher and preferably below 100 (38 ) for proper
F
C
charging.
d.
Let the battery stand for 30 minutes and then check the
specific gravity of each cell with a hydrometer. Correct
the reading to 80 (27 ) by adding 0.004 for each 10
F
C
F
above 80 and subtracting 0.004 for each 10 below 80 .
F
F
F
e.
You should charge the battery if the specific gravity of any
cell measures below 1.270 after correcting to 80 (27 ).
F
C
NOTE
If any of the cells cannot be charged to a specific gravity of at
least 1.270, the battery is not acceptable for this application.
f.
Replace the vent caps when you have completed the above.
5
Flush fuel lines with VV-F-800 diesel fuel prior to starting engine.
6
RETAIN ALL SHIPPING CONTAINERS, BLOCKING, BRACING,
AND PACKING MATERIALS FOR FUTURE USE.
B-1-20

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business