(a)  All inspections require the viewing of external preserved surfaces. This requires lifting of opaque
shrouds or dust covers and the removal of tops or covers not secured to individual boxes or containers.
(b)  No deviation from a 100 percent per quarter visual inspection is required unless control of heat is lost
for a period in excess of 72 hours, or control of heat is lost and the temperature falls through the dew point giving rise to
condensation on the equipment.
(c)  If this condition should occur, 100 percent visual inspection shall be conducted upon the return of heat
within the affected areas.
(d)
Corrective actions shall be taken immediately when unsatisfactory conditions are found.
(5)  Heated storage-periodic inspection. Periodic inspections are not required on items of IPE that have been in
storage I year or less. Periodic inspections shall be scheduled following the first year of storage. If a visual inspection
indicates the formation of incipient deterioration of the preservative in excess of 10 percent of all items, a periodic
inspection shall be performed on all affected items.
(a)  The number of items to be inspected per year shall be of such size to include a total inventory over a 5
year period (assume static condition for each year's sample).
(b)  Items of IPE and OPE shall be scheduled for periodic inspection every 5 years. The inspection shall
include all types of items not previously inspected within the last 5 years.
(c)  The inspection procedures to be followed for heated storage-periodic inspection are the same as those
outlined in 6-6e(2)(c) through (t) above.
(6)  Heated storage-detailed inspection, There is no requirement for detailed inspection of items of WPE and
OPE in storage during the first 5 years.
(a)  If it is found during visual inspection, that there is a formation of incipient deterioration of the IPE or
OPE, or discoloration of the preservative in excess of 10 percent of all items, a detailed inspection shall be performed on
all affected items. If less than 10 percent of the items are affected, corrective actions shall be taken immediately to
eliminate the unsatisfactory conditions.
(b)  The inspection procedures to be followed for heated storage-detailed inspection are the same as those
outlined in 6-6e(3)(b) through (d).
(7)  Noncontrolled humidity storage-visual inspection. Visual inspection shall be performed on all items of IPE
and OPE in storage on a 100 percent per month basis.
(a)  A suggested procedure is to inspect a group of items each week and by the end of the month all items
will have been inspected.