TM 32-5895-227-14&P
Table 7-5. Troubleshooting Monitor Control Panel SB-2600/G - Continued
Item
Trouble symptom
Probable trouble
Corrective action
number
9
Defective relay K7 or
Refer to FO-8.
Check continuity of relay function.
continued
K8
Isolate failure, remove and replace
relay.
10
Inability to transmit.
Defective amplifier No. 3
Refer to FO-8. Interchange amplifier
No. 3 with amplifier No. 1 or No. 2.
Replace defective component on
amplifier No. 4.
Defective mike
Interchange mike from another position.
Replace defective mike.
11
Inability to receive.
Defective amplifier No. 5
Refer to FO-8. Interchange amplifier
No. 5 with amplifier No. 1 or No. 2.
Replace defective component on
amplifier No. 5.
Defective headset
Interchange headset from another
position. Replace defective headset.
7-20
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |