Item
Trouble symptom
Probable trouble
Corrective action
number
18
Special intercom
Defective magnetically-held type SPEC
With the SPEC MON switch held in the
operator is unable
MON switch SW63, SW64, or SW65
closed position, check for presence of
20 Vdc at SPEC MON switch holding
to monitor either the
coil. If 20 Vdc is not present and coil is
third, fourth, or fifth
not energized, switch is defective.
special intercom
Remove and replace switch.
stations.
NOTE
Troubleshooting for the second special intercom circuit and the first row of the special monitor
buttons (located at the right-hand side of the switchboard) will be the same as the second r ow
of special monitor buttons, since the function of both rows of the switches are the same; however,
switch numbers will differ.
19
Special intercom
Defective relay K27, K29, or K31
Special intercom operator No. 1 to
monitor special intercom stations
operator No. 1 is
through the first row of SPEC MON
unable to talk to
switches, then depress SPEC ICOM
either the 3rd, 4th, or
switch SW62 and check for presence of
5th special intercom
20 Vdc at relay coils K27, K29, or K31.
stations being
If 20 Vdc is present and relay is not
monitored by the first
energized, relay is defective. Remove
row of SPEC MON
and replace relay.
switches.
20
Special intercom
Defective relay K28, K30, or K32
Special intercom operator No. 2 to
monitor special intercom stations
operator No. 2 is
through the second row of SPEC MON
unable to talk to
switches, then depress SPEC ICOM
either the 3rd, 4th, or
switch SW66 and check for presence of
5th special intercom
20 Vdc at relay coil K28, K30, or K32. If
stations being
20 Vdc is present and relay is not
monitored by the
energized, relay is defective. Remove
SPEC MON
and replace relay.
switches.
21
Initiated call to
Defective relays K22 through K26
Depress RICS switch at special intercom
SB-2602/G by any
stations 1 through 5 and check for
one of the SPEC
presence of 20 Vdc at relay coil. If 20
ICOM stations No. 1
Vdc is present and coil is not energized,
through No. 5 does
relay is defective. Remove and replace
not blink special
relay.
intercom stations
RICS light, or the SB-
2602/G SPEC ICOM
light.