Step 4.
Disconnect both leads 518 (1) from FLOODLIGHTS switch (2). Connect
multimeter  to  FLOODLIGHTS  switch.  Set  FLOODLIGHTS  switch  ON.  If
multimeter indicates continuity, repair lead 518 between floodlights and
FLOODLIGHTS switch, refer to page 2-66. If multimeter indicates infinity,
repair FLOODLIGHTS switch, refer to page 2-297. Set FLOODLIGHTS
switch OFF. Connect leads.