TM-9-2350-238-20-2 Crane (CAB) Components Recovery Vehicle Full-Tracked: Light Armored M578 (
Next
CAB FILTER lNSTALLATION ­Cab Air Purifier Circuit. (Cont) - TM-9-2350-238-20-20085
TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Disconnect lead 415 (1) from input side of circuit breaker (2). Place red
Step 3.
probe
in
lead
415.
Ground
black
probe.
Set
MASTER
switch
ON.
If
multimeter  indicates  about  24  volts,  go  to  step  4.  If  multimeter  indicates  no
voltage,  repair  lead  415  between  dome  light  connector  and  circuit  breaker,
refer  to  page  2-66.  Set  MASTER  switch  OFF.  Connect  lead.