5
Loosen hose clamp (9) attaching air
ventilator (10) to slipring ducting hose
(11) .
6
Loosen hose clamp (12) and remove air
ventilator (10).
7
If damaged, remove six marker bands
(13) .
8
Loosen hose clamp (14) and remove air
ventilator (15) from rigger/gunner cupola.
9
Remove plain hexagon nut (16), machine
screw (17), lockwasher (18), and loop
clamp (19).
10
Remove airflow deflector (20) from crane
operator's cupola.
11
Loosen three hose clamps (21).
12
Remove three ducting hoses (22).
13
Remove hexagon head capscrew (23),
lockwasher (24), and air deflector heater
tube adapter (25).