1 Untag and connect heater control box to driver's heater wiring harness (1) plug connector to
vehicular heater (2).
2 Untag and connect plug connector (3) to driver's heater electrical control box (4).
3 Untag and connect shell connector (5) to line connection.
4 Untag and connect cable terminal (6) to dome light assembly (7).
5 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
1 Untag and connect bulkhead disconnects to master relay and circuit breaker special cable
assembly (1) plug connector to master relay assembly (2).
2 Install new gasket (3) and connect bulkhead disconnects to master relay and circuit breaker
special cable assembly (1) to bulkhead disconnect. Secure receptacle connector (4) with four
screws (5).
3 Untag and connect six shell connectors (6) to line connections.
4 Untag and connect plug connector (7) to vehicle bus receptacle connector.
5 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.