NOTE
Steps 6 thru 14 pertain to adjustment of neutral position switch.
6
Set transmission shift control lever to N.
Loosen two hexagon head capscrews (10) and move bracket (4) to position roller guide (7) in
7
shift rod lever detent (13) with roller guide just touching lever.
Set multimeter to OH MS-RX I scale and zero the multimeter. Connect multimeter leads (14) to
8
two neutral position sensitive switch shell connectors (15).
9
Multimeter must indicate 0 ohms with neutral position sensitive switch (3) closed. If not, move
bracket (4) until multimeter indicates 0 ohms. Tighten hexagon head capscrews (10).
10
Set transmission shift control lever to 1. Multimeter must indicate infinity with neutral position
sensitive switch (3) open. If not, loosen hexagon head capscrews (10) and move bracket (4)
until multimeter indicates infinity. Tighten hexagon head capscrews.
Set transmission shift control lever to N. Multimeter must indicate 0 ohms. If not, repeat steps
11
9 and 10.
12
Set transmission shift control lever to every shift position. Check multimeter indication at each
position. Multimeter must indicate infinity at positions 1, 2, 3, 4, R1, and R2, and must indicate
0 ohms at N. If not, repeat steps 9 thru 11.
13
Remove multimeter leads (14) and connect three shell connectors (15) at line connections.
14
Install new Iockwire (16) on two hexagon head capscrews (10).