2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 2.
Disconnect lead 402R from driver's heater control box wiring harness.
Place red probe in lead 402R. Ground black probe. Set MASTER switch
ON. Set START-OFF-RUN switch to START. If multimeter indicates about
24 volts, go to step 3. If multimeter indicates no voltage, repair lead 402R
between disconnect and driver's heater control box wiring harness. Refer to
page 2-371. Set MASTER switch OFF. Set START-OFF-RUN switch OFF.
Connect lead.