2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
BA. AIR BOX HEATER CIRCUIT.
Step 1.
Set PUMP AND HEATER INGNITER and MASTER switches OFF. Discon-
nect lead 76 from connector near driver's seat. Place red probe on connect-
or receptacle. Ground black probe. Set MASTER Switch ON. If multimeter
indicates about 24 volts, connect lead and go to step 3. If multimeter indi-
cates no voltage, go to step 2. Set MASTER switch OFF.