Click here to make tpub.com your Home Page

Page Title: AERATION DETECTOR CIRCUIT. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Place red probe in pin socket C. Ground black probe.
Step 6.
indicates 0 ohms, connect electrical lead to low engine coolant level
warning light and go to step 7. If multimeter does not indicate 0 ohms, low
engine coolant level warning switch is operating properly.
To access aeration detector, remove engine deck assembly. Refer to page
Step 7.
2-935. Disconnect ground lead from aeration detector. Place red probe on
ground lead. Ground black probe. If multimeter indicates 0 ohms, go to
step 9. If multimeter does not indicate 0 ohms, repair ground lead. Refer to
page 2-371. Connect ground lead.
2-204

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business