2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
Disconnect instrument (gage) panel wiring harness. Place red probe on pin
Step 4.
F (lead 27). Ground black lead. Set MASTER switch ON. Set INST switch
ON. If multimeter indicates about 24 volts, repair lead 27 between
receptacle and ENGINE-XMSN TEMP-PRESS warning light. Refer to page
2-371. If multimeter indicates no voltage, go to step 5. Set MASTER
switch OFF. Set INST switch OFF.