Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 3.
Place red probe in socket (+) of slave receptacle. Place black probe in
socket (-) of slave receptacle. Set MASTER switch ON. If multimeter
indicates about 24 volts, go to step 4. If multimeter indicates no voltage,
repair lead 49 between slave receptacle and voltage regulator. Refer to
page 2-371. Set MASTER switch OFF.
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 4.
To access bulkhead disconnect, remove driver's seat, refer to page 2-952;
and remove driver's compartment aft cowl, refer to page 2-928. Discon-
nect wiring harness at bulkhead disconnect. Place red probe in socket
(lead 2). Ground black probe. Set MASTER switch ON. If multimeter
indicates about 24 volts, go to step 5. If multimeter indicates no voltage,
repair lead 2 between bulkhead disconnect and generator-regulator. Refer
to page 2-371. Set MASTER switch OFF. Connect wiring harness at
bulkhead disconnect.