TM 9-2350-238-20-1
Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION
INSTRUCTIONS FOR M578 RECOVERY VEHICLE (CONT)
Not Fully Mission
Procedure
Item To Check/
Interval
Item
Capable If:
Service
No.
Final Drive
S
16
Drain and Fill
Oil will be hot after operation.
NOTE
Drain only after operation.
Class Ill leaks
Remove level plug (1) and drain plug (2) and
a.
drain oil into a suitable container.
Dry cleaning solvent (SD2) is toxic and
flammable. Wear protective goggles and
gloves and use only in well-ventilated area.
Clean drain plug with dry cleaning solvent (item
b.
16, appx C) and install.
Remove fill plug (3) in final drive saddIe (left and
c.
right sides).
Slowly add OE/HDO or OEA (item 28 or 29,
d.
appx C) through fill plug hole (3) until oil flows
from level plug hole (1).
Clean plugs (1) and (3) with dry cleaning solvent
e.
(item 16, appx C) and install.
Repeat steps for other side.
f.
2-31