Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION
INSTRUCTIONS FOR M578 RECOVERY VEHICLE (CONT)
Procedure
Not Fully Mission
Item To Check/
Item
Interval
Capable If:
Service
No.
Class Ill leaks.
Drive vehicle over 4 x 4 x 24-in. (10 x 10 x 61-cm)
Lockout Cylin-
9
Lockout cylinder
wood block with suspension locked. Lockout cylinder
ders (cont)
(cont)
is damaged or
is damaged if roadwheel arm moves upward as
moves upward
roadwheel rides over block. Replace damaged lock-
as wheel rides
out cylinders. Refer to page 2-883.
over block.
Class Ill leaks.
Inspect for leaks or damage. Replace leaking seals
Wheels, Arms,
10
S
Any loose at-
or gaskets. Replace worn or damaged wheels.
and Hubs
taching wheel
Refer to page 2-848. Tighten wheel attaching nuts
nuts or damaged
(1) to 325 ft-lb (440 N-m) dry.
wheels.
Any broken wir-
Inspect, tighten, or connect wiring terminals and
Electrical Wir-
11
S
ing terminals or
ing
connections. Tape cables or harnesses that are
frayed wires and
frayed or have broken insulation. Repair damaged
broken connec-
connectors. Refer to page 2-373.
tor.
Engine starter
Start engine and listen for unusual noises, such as
Starting
12
S
will not engage,
clicking or laboring. If unusual noises are heard,
System
any unusual
troubleshoot starter motor circuit. Refer to page
noises.
Generator volt-
Check generator voltage and amperage output. If
Generator or
S
13
age and amper-
generator warning light on instrument panel lights,
Voltage Con-
age output ex-
troubleshoot generator charging circuit. Refer to
trol System
ceeds limits, or
generator warn-
ing light comes
on.
14
Engine Oil
S
Filter and
Oil will be hot after operation.
Drain
NOTE
Drain only after operation.
q
Drain when notified by the Army
q
Oil Analysis Program (AOAP)
laboratory.
If AOAP laboratory support is not
q
available, drain every 1500 mi
(241 4 km), 150 hr, or semiannu-
ally, whichever occurs first.