Click here to make tpub.com your Home Page

Page Title: Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION INSTRUCTIONS FOR M578 RECOVERY VEHICLE (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2350-238-20-1
Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION
INSTRUCTIONS FOR M578 RECOVERY VEHICLE (CONT)
Not Fully Mission
Procedure
Item To Check/
Interval
Item
Capable If:
Service
No.
Auxiliary
3
Drive Clutch
(cont)
Housing
Breather, Oil
Level, and Fill
(cont)
Remove breather (1), clean with dry cleaning
b.
solvent (item 16, appx C), and install.
Check that oil level is at FULL mark on gage
c.
(2).
Remove fill plug (3) and fill with OE/HDO or
d.
OEA (item 28 or 29, appx C) as necessary.
Clean fill plug (3) with dry cleaning solvent (item
e.
16, appx C) and install.
Fixed Fire
S
4
Extinguisher
System
High pressure CO2 gas is used in this
equipment. Keep face and body clear of
release valves. Failure to observe safety
precautions may result in injury or death.
Inspect fire extinguisher cylinder data plate to
a
ensure that a hydrostatic test has been per-
formed within the past 12 years. Faulty extin-
guishers or those beyond the test time limit (12
years) shall be declared unserviceable and re-
placed.
2-23

Privacy Statement - Press Release - Copyright Information. - Contact Us