11-28. GLADHAND REPLACEMENT (CONT)
h. Rear Emergency Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing.  To avoid injury or death,
keep away from open fire and use in
well-ventilated area.  If pipe thread
seating compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads.  Do
not  apply  compound  at  hose
connections.  Damage to equipment
may result.
(1) Coat threads of fitting (1) and elbow (2) with pipe
thread sealing compound.
(2) Install gladhand (3) on fitting (1).
(3) Install fitting (1) on bracket (4) with new
lockwasher (5) and nut (6).
(4) Install elbow (2) in fitting (1).
(5)
Install hose (7) on elbow (2).
(6)
Install dummy coupling (8) on gladhand (3).
i. Trailer Service and Emergency Removal
(1) Remove gladhand (1) from mounting bracket
(2).
(2) Remove hose (3) from fitting (4).
(3) Remove fitting (4) from gladhand (1).