CIRCUIT BREAKER REPLACEMENT
Up
TM-9-2320-360-20-2 Truck Tractor M1070 8x8 Heavy Equipment Transporter (HET) NSN
Next
INSTRUMENT PANEL REPLACEMENT
TM 9-2320-360-20-2
7-12.
CIRCUIT BREAKER REPLACEMENT (CONT)
b. Installation
CAUTION
Some circuit breakers have dedicated
ground wires. Many circuit breakers
are connected by use of a common
bus bar. Bus bar must be installed at
point from which it was removed.
NOTE
If installing 5 amp DDEC circuit
breaker with prong terminals, do
steps (1) and (3) thru (7).  For all
other circuit breakers, go to step (2).
(1) Position 5 amp DDEC circuit breaker (1)
with stud through electronic control box
assembly (2).
(2) Position circuit breaker (3) in electronic
control box assembly (2).
(3) Install nut (4) on stud of circuit breaker (1
or 3).
(4) Install wires (5 and 6) on 5 amp DDEC
breaker (1).
(5) Connect wire (7) to circuit breaker (3).
(6) Install bus bar (8) (if applicable) and wire
(9) on rear of circuit breaker(s) (3) with
new lockwashers (10) and screws (11).
(7) Install cover (12) on electronic control box
assembly (2) with eight screws (13).
c. Follow-On Maintenance
Connect batteries (para 7-61).