Click here to make tpub.com your Home Page

Page Title: REMOVAL
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-285-24-2
3-24.
BRAKE CONTROLS MAINTENANCE (CONT)
b.
Quick Release Valves (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Rear frame,
Quick release
Remove from
Turn counterclockwise
above left
valve
fitting
brake air
chamber
2
Rear frame,
Quick release
Remove from
Turn counterclockwise
above right
valve
fitting
brake air
chamber
DISASSEMBLY
3
Valve,
a
Four screws (1)
Remove
quick
b
Cover (2) and
Separate
release
body (3)
c
Insert (4)
Remove
d
Diaphragm (5)
Remove and
and O-ring
discard
(6)
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and
don't smoke when using it. Failure to do so could cause serious injury.
If you become dizzy while using cleaning solvent, get fresh air and
medical attention immediately. If contact with skin or clothes is made,
flush with large amounts of water. If contact with eyes is made, wash
eyes with water and obtain medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when
drying parts with compressed air. Failure to do so could cause serious
injury to eyes and possible blindness. If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention
immediately.
3-176

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business