2-78. FIFTH WHEEL HYDRAULIC SYSTEM MAINTENANCE (CONT)
c. Hydraulic Reservoir (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
5
Hydraulic
Return line filter
Remove
reservoir
head and piping
CLEANING
6
a. Rubber pads
Clean using detergent solution; dry with
(10)
clean cloths
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is  toxic and flammable.  Wear
protective goggles and gloves and use only in a well ventilated area. Avoid contact with
skin, eyes, and clothes and don't breathe vapors.  Do not use near open flame or
excessive heat and don't smoke when using it. Failure to do so could cause serious
injury. If you become dizzy while using cleaning  solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of
water.  If contact with eyes is made,  wash eyes with water and seek medical aid
immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with
compressed air.  Failure  to do so could cause serious injury to eyes and possible
blindness. If you hurt your eyes or if a foreign object is blown into your eyes, seek
medical attention immediately.
b. Hydraulic
Clean exterior with cleaning solvent P-D-680
reservoir (9)
and stiff bristled brush. Dry thoroughly
with compressed air. Pour cleaning solvent
P-D-680 into reservoir; agitate reservoir
to thoroughly clean interior. Pour clean-
ing solvent out, and dispose of properly.
Dry interior of reservoir with compressed
air. When interior is thoroughly dry,
flush reservoir interior with clean hyd-
raulic oil. Then drain hydraulic oil and
dispose of properly. Dry reservoir inter-
ior with compressed air
c. All other parts
Clean using cleaning solvent P-D-680; dry
with compressed air
2-897