2-26.
INSTRUMENT PANEL MAINTENANCE (CONT)
g.
Instrument Panels (cont).
(3)
Right Panel (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Cab,
a. 10 screws
Remove
inside
b. Right panel
Remove
Lift from cab
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of water. If contact
with eyes is made, wash eyes with water and seek medical aid immediately.
2
Screws and right
Clean
Use cleaning solvent P-D-680;
panel
dry with clean cloths
INSPECTION
3
a. Right panel
Inspect
Replace if cracked
b. Screws
Inspect
Replace if cracked or threads
damaged
INSTALLATION
4
Cab,
a. Right panel
Position
Align mounting holes
inside
b. 10 screws
Install and
tighten
c. Fifth wheel and
Install
gear shift
control
mounting
plate
2-285
TM 9-2320-285-24-1
2-26.
INSTRUMENT PANEL MAINTENANCE (CONT)
g.
Instrument Panels (cont).
(3)
Right Panel (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (cont)
5
Cab,
a. Right instru-
Install
Para 3-12d
under
ment panel
hood
wiring