2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
a. Switches (cont)
(1) Ignition Switch (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
3
WARNING
(cont)
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water and seek medical aid immediately.
b. All other parts
Clean
Wipe with clean cloth moist-
ened with cleaning solvent
P-D-680; allow to air dry
INSPECTION
4
All parts
Inspect
Replace if cracked, broken,
insulation frayed, or
threads damaged
INSTALLATION
5
Instrument
a. Nut (12)
Install
On ignition switch (11)
panel
b. Tumbler (13)
Install
If removed. Depress tumbler
(13) lock to install
c. Ignition switch
Position
In instrument panel, with
(11)
key removed
d. Nut (10)
Install and
tighten
e. Electrical
Connect
To BAT terminal of ignition
leads
switch (11)
(3 and 4)
f. One nut (1) and
Install and
Secures leads (3 and 4)
lock washer
tighten
(2)
g. Electrical
Connect
To IGN terminal of ignition
leads
switch (11)
(6 and 7)