2-25.
STARTING SYSTEM MAINTENANCE (CONT)
a.
Solenoid and 70 AMP Circuit Breaker (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
TESTING (cont)
10
b. Ground wire
Check for open ground wire.
(cont)
(23)
a. If ground wire (23) is open, replace
b. If ground wire is okay, check for
voltage at terminal (26) connected to
solenoid (31) large terminal
c.
If voltage is present when key switch
is in START position, check starter
d. If voltage is not present when key
switch is in START position, solenoid
(31) is defective and must be replaced
c. Circuit Check for voltage at terminal to which red
breaker (40) wire (15) is connected.
a. If voltage is present, check for volt-
age at circuit breaker (40) terminal to
which red wire (36) is connected. If
voltage is not present, press circuit
breaker red button and recheck for
voltage. If voltage is not present
replace circuit breaker (40). If red
button pops out, a short circuit exists
in the wiring and must be located and
repaired
b. If voltage is not present, check red
wire (15) connected to solenoid (31)
for an open condition. If wire (15) is
okay, check wire (11) and cable connec-
ted to battery; repair as necessary
11
Battery
Battery ground
Disconnect
box
cable
12
Starter
a. Shield (3)
Position
Over solenoid (31)
b. Two capscrews
Install and
(2) and nuts
tighten
(1)
13
Battery
Battery ground
Connect
box
cable