LIGHT CONTROL RHEOSTAT - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Check operation (TM 9-2320-270-10).
2. Close instrument panel (page 4-244).
TASK ENDS HERE
LIGHT SWITCH
This task covers:
a. Removal (page 4-288)
b. Installation (page 4-289)
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, flat-tip, 1/4-inch,
Screwdriver, flat-tip, 3/8-inch
Equipment Condition
Wrench, box, 9/16-inch
Battery ground cable disconnected
Materials/Parts
Instrument paneI open (page 4-244).
Lockwashers, wire to terminal
Tag, marking (item 18, appendix C)
ACTION
ITEM
REMARKS
LOCATION
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to dis-
connect battery ground cable can cause personal injury and damage to electrical
system.
NOTE
Tag wires according to general maintenance instructions (page 4-1).
1. Terminal (1)
Screw (2), lock-
s. Using 1/4-inch screwdriver, unscrew
and take off.
washer (3), and
wire 084 (4)
b. Get rid of Iockwasher (3).
s. Using 1/4-inch screwdriver, unscrew
2. Terminal (5)
Screw (6), lock-
washer (7), and wire
and take off.
b. Get rid of Iockwasher (7).
017 (8) or 08A (9)
4-288