TM 9-2320-270-20-1
ETHER STARTING KIT
This task covers:
c. Installation (page 4-122)
a. Removal (page 4-118)
b. Cleaning and Inspection (page 4-121)
INITIAL SETUP
Materials/Parts
Tools
Lockwasher (four required)
Pliers, diagonal cutting
Wrap, tie (item 24, appendix C)
Pliers, slip-joint, straight-nose
Screwdriver, flat-tip, 1/4-inch,
Personnel Required
4-inch blade
Wrench, adjustable, 10-inch
One
Wrench, open-end, 3/8-inch
Wrench, open-end, 7/16-inch
Equipment Condition
Wrench, open-end, 9/16-inch
Wrench, open-end, 5/8-inch
Right side of hood open and right and left
Wrench, open-end, 7/8-inch
side panels removed (TM 9-2320-270-10).
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Ether fumes are flammable, under pressure, and can explode. To avoid serious injury
or death, do not smoke, allow open flame nearby, or hit the ether cartridge with tools.
Pull open.
Ether cylinder
1. Firewall (1)
mounting clamp (2)
Unscrew and take out.
Ether cylinder (4)
2. Mounting clamp (2)
and valve
assembly (3)
a. Using 3/8-inch wrench, unscrew and
3. Mounting clamp (2)
Two screws (5) and
take out.
to firewall (1)
b. Get rid of lockwashers (6).
Take off.
Mounting clamp (2)
4. Firewall (1)
4-118