AIR SYSTEM LEAK CHECK - CONTINUED
3. Air valve exhaust parts may produce up to a 1-inch (2.5 cm) bubble in one minute. If soap
solution foams or makes a bubble faster, replace valve.
4. Air line connections and air chambers should not leak at ail. Any bubbling of soap solution is
cause to repair or replace connection or air chamber.
FLUID DISPOSAL
Get rid of contaminated drained fluids in accordance with your unit's Standard Operating Procedures
(SOP).
Section Il. ENGINE SYSTEM MAINTENANCE
Page
Page
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Rocker Arm and Valve Cover and
Oil Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-12
Oil Level Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-30
Rocker Arm and Valve Cover and
Gasket for Early T Engine . . . . . . . . . . . . . . . . . . . . . . 4-18
This task covers:
Engine Oil Servicing (page 4-10)
lNITIAL SETUP
Tools
Materials/Parts
Handle, ratchet, 3/8-inch drive
Container
Socket, 9/16-inch, 3/8-inch drive
Gasket
Socket, 5/8-inch, 3/8-inch drive
Oil filter element
Wrench, 5/8-inch, open-end
Personnel Required
One