TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 6.
Go to terminal for wire no. 279 (5) on fifth gear switch (6) on shift tower (4).
Using multimeter set at 30 vdc, put red probe on terminal and black to probe to
good ground.
If meter reads no voltage, put key in OFF position and notify direct
support maintenance.
Step 7.
With main transmission in fifth gear, go to terminal for wire no. 154 (7) on fifth
gear switch. Using multimeter set at 30 vdc, put red probe on terminal and
black probe to good ground.
If meter reads no voltage, put key in OFF position replace fifth gear
3-189