TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
35. HORN INOPERATIVE CONTINUED.
At two horns (1), using multimeter set at 30 vdc, put red probe on horn
Step 7.
terminal for wire no. 168 (2) and black probe to good ground. Have assistant
push horn button, hold and release.
If meter reads no voltage, close right side of hood (TM 9-2320-270-10)
and notify direct support maintenance.
Take off wires to two horns (1). Using multimeter set at RX1, put probes on horn
Step 8.
contacts (3).
If meter does not read zero, replace horns (page 4-438).
Take off ground wires (4). Using multimeter set at RX1, put probe on each end.
Step 9.
a. If meter reads zero, close right side of hood (TM 9-2320-270-10)
and notify direct support maintenance.
b. If meter does not read zero, put on wires and go to BOTH HEAD-
LIGHTS DO NOT WORK, and do steps 6 thru 9 (page 3-48).
3-100