TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. FUEL LEVEL GAGE SHOWS INCORRECT FUEL LEVEL.
NOTE
If fuel level gage shows zero fuel during operation, go to step 4.
Perform step 1 under ENGINE USES TOO MUCH FUEL (page 3-31).
Step 1.
Drain fuel tanks (page 4-32). TURN KEY TO ON. Using multimeter set at 30 vdc,
Step 2.
put red probe on fuel sender terminal (1) and black probe on terminal (2).
If meter does not read 8 to 10 volts, put key in OFF position and replace
fuel sender (page 4-390).
PUT IGNITION KEY in OFF position. Fill fuel tank (TM 9-2320-270-10). Put
Step 3.
IGNITION KEY in ON position. Using multimeter set at 30 vdc, put red probe on
fuel sender terminal (1) and black probe on terminal (2).
a. If meter does not read 3 to 6 volts, put key in OFF position and
replace fuel sender (page 4-390).
b. If meter does read 3 to 6 volts, put key in OFF position and replace
fuel gage (page 4-268).
TA239621
3-32