TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Start engine (TM 9-2320-270-10) and compare density of exhaust smoke to
chart below.
If smoke is 40 percent density or greater, shut down engine
(TM 9-2320-270-10) and notify direct support maintenance.
Step 4.
Shut down engine (TM 9-2320-270-10). Disconnect fuel return hose (3) from
right fuel tank elbow (4) and put end of hose (3) in container (at least
2-gallon capacity). Start engine (TM 9-2320-270-10) and run at 1,800 rpm
for 1 minute, shut down engine (TM 9-2320-270-10). Check amount of fuel in
container.
If there is less than 0.9 gallons of fuel in container, replace fuel filter
(page 4-110) and fuel strainer (page 4-114), connect fuel return hose
(3) to elbow (4), install right side panel and close right side of hood
(TM 9-2320-270-10).
TA239610