TM 9-2320-269-34-1
CONSOLE TACHOMETER AND OUTRIGGER HYDRAULIC SOLENOID WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
64
Center solenoid (1)
Dark brown wire
Screw on, and tighten using 3/8-inch
and left front
(3), new lock-
box-end wrench.
terminal (2)
washer (4), and
nut (5)
65
Bottom solenoid (6)
Two white wires
Screw on, and tighten using 318-inch
and right front
(8) and (9), new
box-end wrench.
terminal (7)
lockwasher (10),
and nut (11)
66
Relay box (12)
Red auxiliary
Put through.
pump wire (13)
67
Bottom solenoid (6)
Red auxiliary pump
Screw on, and tighten using 1/2-inch
and right front
wire (13), new
box-end wrench.
terminal (14)
lockwasher (15),
and nut (16)
68
Clamp (17)
Two screws (18)
Tighten using 3/16-inch flat-tip
screwdriver.
TA238327
2-584