RIGHT WATER OUTLET - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT- CONTINUED
10.
Right water
Look for cracks, breaks, and dents.
outlet (1)
ASSEMBLY
11.
Water pipe (2)
Two new packings (3)
Put on.
12.
Right water
Water pipe (2)
a. Put outlet (1) in vise.
outlet (1)
b. Slide in pipe (2) with two packings (3).
13.
Pipe plug (4)
Using 9/16-inch open-end wrench, screw
in and tighten.
14.
Sending unit (5)
Using 3/4-inch open-end wrench, screw in
and tighten.
INSTALLATION
15.
Right water outlet
Wire lead (6)
Screw on, and tighten using 7/16-inch
(1) and sending
and nut (7)
open-end wrench.
unit (5)
16.
Front crankcase
Right water
Put in position.
cover (8) and right
outlet (1) and new
cylinder head (9)
gasket (10)
17.
Right water
Two new lockwashers
Screw in, and tighten using 9/16-inch
outlet (1)
(11), wire clip
socket and ratchet handle with 3/8-inch
bracket (12), oil
drive.
level gage assembly
(13), and screws (14)
18.
Wire clip
Wire clip (15),
Screw on, and tighten using 7/16-inch
bracket (12)
screw (16), and
open-end wrench, 7/16-inch socket, and
nut (17)
ratchet handle with 3/8-inch drive.