WATER OUTLET - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
For more Information on how to inspect parts, go to General Maintenance Instructions (page 2-46).
Replace damaged or defective parts as necessary.
4.
All metal parts
a. Look for cracks and breaks.
b. Look for damaged threads.
ASSEMBLY
5. Water outlet (1)
Nipple (2)
a. Secure outlet (1) in vise.
b. Screw In, and tighten using 11/16-inch
open-end wrench.
6.
Plug (3)
a. Screw in, and tighten using 9/16-inch
open-end wrench.
b. Take outlet (1) out of vise.
TA238168
2-390