SCOPE
This chapter gives procedures to check the elevation fire control quadrant for faults you can see when it is
r e c e i v e d in the DS/GS shop. It also tells you what part of this volume to go to for various repairs. A
complete inspection should be made and all faults listed on DA Form 2404 before taking any
maintenance actions. The performance test in Volume I, Chapter 2 should be done after doing the
i n s p e c t i o n upon receipt.
INSPECTION UPON RECEIPT
TOOLS:
Fine file or scraper
3 / 1 6 " ,  1 / 8 " , 1 / 4 " , f l a t tip screwdriver
.070" jewelers screwdriver
L e v e l vial wrench (App C)
Artist's brush
C l o t h (item 1, App A)
SUPPLIES:
P r i m e r (item 5, App A)
Paint (item 3, App A)
PERSONNEL:
One
REFERENCES:
TM
43-0139
for
painting
Cleaning
JPG41C for:
R e m o v i n g nicks and burrs
Completing DA Form 2404
EQUIPMENT CONDITION: Elevation fire control quadrant in vehicle or on work bench
II-3-1