INSPECTION UPON RECEIPT (CONT)
3-2.
Reference
Procedure
Maintenance Action
Step
If cracks or dents are
...
1.
Clean exterior of ballistic drive and
found, tell your
check for cracks or dents.
supervisor.
TM 9-254
Clean
2.
Check ballistics drive for dirt and
corrosion.
Send ballistics drive to
3.
Check ballistic drive for free
depot for repair.
movement of cross shaft assembly
(1) in left and right support
assemblies (2) while operating
manual elevation hand pump (3).
Send ballistics drive to
4.
Check surface (4) of left and right
depot.
mounting supports (2) for damage.
Tighten. Replace if
5.
Using fabricated Allen wrench,
missing.
check four screws (5) are tight.
Tighten. Replace if
6.
Using fabricated Allen wrench,
missing.
check four screws (6) are tight.
JPG 41C
Install lead seals.
7.
Check two lead seals (7 and 8) are
installed.
Repair level
8.
Check fire control level (9) is not
damaged.
GO TO FRAME 2